Menu
Your Cart

    Detailed Project Report on water for ampoule (water ampoul of 5ml/10ml/30 ml manufactured which are used for dry injection and dry syrps)

    Detailed Project Report on water for ampoule (water ampoul of 5ml/10ml/30 ml manufactured which are used for dry injection and dry syrps)
    Detailed Project Report on water for ampoule (water ampoul of 5ml/10ml/30 ml manufactured which are used for dry injection and dry syrps)
    ₹ 0 INR
      Why Choose Us
      • More than 40 years of experience
      • Managed by expert industrial consultants
      • ISO 9001-2015 Certified
      • Registered under MSME, UAM No: DL01E0012000
      How we work
      • 24/5 Research Support
        Get your quesries resolved from an industry expert. Ask your queries before report or book purchase.
      • Custom Research Service
        Speak to the our consultant to design an exclusive study to serve your research needs.
      • Quality Assurance
        All reports are prepared by highly qualified consultants & verified by a panel of experts.
      • Information Security
        Your personal & confidential information is safe & secure.

      WATER FOR AMPOULE
      (WATER AMPOULE OF 5ML./10ML./30ML.
      MANUFACTURED WHICH ARE USED FOR DRY INJECTIONS AND DRY SYRUPS)

      [CODE NO.3087]  


      Water for injection by definition is water that is intended for use in the manufacture of parenteral (i.e. injectable) drugs whose solvent is water. The USP (United States Pharmacopeia) defines this as highly purified waters containing less than 10 CFU/100 ml of Aerobic bacteria. These waters should also have fewer than 500 ppb of total organic carbon, fewer than 0.25 EU/ml endotoxins, and a conductivity of less than 1.3uS/cm @ 25 C.

      To begin, let’s start by looking at how Water for Injection is made. The USP allows WFI to be produced by one of two means; either distillation or reverse osmosis. Prior to making it to the still, however, supply water has to go through extensive pretreatment. Pretreatment usually includes various filtration steps, removal of chlorines through the use of activated
      carbon beds, and percolation of water through ion exchange resins to remove residual ionic compounds. What is the purpose of all this pretreatment? By pretreating the water, we effectively reduce the conductivity of the water, as well as the level of organic contaminants.

      Once the water makes it through these pretreatment steps, it goes to the still. What happens in a WFI still? Distillation, of course. When water is distilled, it heated until it is a vapor, stripping the heavier ions, particulates, and endotoxins from the water. There are both single and multiple effect stills and which one is best for you is determined by how much
      WFI you are trying to generate. There are also vapor compression stills available that can make WFI.  Regardless of what kind of still you are using, the basic process is the same- the water vapor is passed through a series of tubes and recondensed, resulting in WFI.

      We get WFI from a process called reverse osmosis. In reverse osmosis, or RO, water is forced through a semi-permeable membrane and the pores in that membrane reject dissolved ions, salts, and organic compounds. This is filtration on a molecular and ionic level. The quality of water, temperature, PH, and flows rates are all critical in RO as the membranes used can foul easily. Reverse osmosis systems rely on booster pumps to increase pressure across membranes, storage tanks, and sophisticated controls for bulk WFI preparation. RO systems are capable of producing 600-50,000 gallons per day of WFI.

      So what is done with WFI after it is produced to ensure the water stays at water for injections quality? It either needs to be used quickly (usually same day) or put in a state that allows it to maintain its efficacy. How do you make sure WFI stays as WFI? You need to minimize microbial growth. This is accomplished by maintaining it at high temperatures and keeping it in motion.  Normally WFI is kept at 90 degrees C and recirculated through a distribution loop at a minimum velocity of 5 feet per second.

      To ensure there is no contamination of entering or building up in the distribution system, the piping is normally highly polished, at least 20 Ra, often with electropolish.  Any ventilation or vent filters are usually sterile membranes of at least 0.2 uM. Vent filter, commonly found on tanks, are often heat traced or steam jacketed. Why is that? Well, when WFI
      comes in from the still, it can be very hot. The heat can cause it to flash off and enter the filter. Once the steam makes contact with the vent filter, which if not heat traced will be cooler than the tank, the vapor will recondense and cause the vent filter to blind. When you go to pump that tank out, you would then pull a vacuum and could cause the tank to
      collapse.

      Other common pieces of equipment used to ensure system integrity include double sheet shell and tube heat exchangers and weir type diaphragm valves.  EPDM is probably the most common gasket material we see in a WFI system.

      Because the conductivity of WFI is so low, it is considered “ion hungry”, ready to leach ions out of any surface it comes in contact with. That makes the water very abrasive. That means we use centrifugal pumps with single or double mechanical seals and hard seal faces, the most common and robust being either silicon carbide or tungsten carbide.

      COST ESTIMATION

      Plant  Capacity                              :    200000.00 Ampoules/day                                       
      Land & Building (700 Sq.MT)    :    Rs. 94.00 Lacs
      Plant & Machinery                        :    Rs. 4.00  Cr
      Working Capital for 2 Months    :    Rs. 1.44  Cr
      Total Capital Investment             :    Rs. 6.58  Cr
      Rate of Return                              :    25%
      Break Even Point                         :    57%


      INTRODUCTION    
      WATER FOR INJECTION    
      USES    
      B.I.S. SPECIFICATION    
      WATER FOR INJECTION    
      MARKET SURVERY    
      PHARMA GIANTS RAISE THEIR R&D SPENDING    
      RAW MATERIALS FOR INJECTION WATER AMPOULES    
      PROCESS OF DISTILLATION    
      DIFFERENT METHOD FOR WATER FOR INJECTION    
      TECHNOLOGIES FOR WATER FOR INJECTION    
      MANUFACTURING PROCESS    
      PACKAGING OF WATER IN AMPOULES    
      PROCESS FLOW DIAGRAM    
      PROCESS IN DETAILS FOR WATER FOR INJECTION (WFI)    
      MULTI EFFECT STILL DIAGRAM    
      VAPOUR COMPRESSION STILL SCHEMATIC    
      PRODUCTION OF WATER FOR INJECTION FOR THE PHARMACEUTICAL
      AND BIO-PHARMACEUTICALS    
      FORM-FILL-SEAL TECHNOLOGY & PROCESS    
      PLANT LAYOUT    
      SUPPLIERS OF RAW MATERIALS    
      SUPPLIERS OF PLANT & MACHINERY    

      APPENDIX – A:

       1.      COST OF PLANT ECONOMICS  
       2.      LAND & BUILDING                                      
       3.      PLANT AND MACHINERY                                  
       4.      FIXED CAPITAL INVESTMENT                             
       5.      RAW MATERIAL                                         
       6.      SALARY AND WAGES                                     
       7.      UTILITIES AND OVERHEADS                              
       8.      TOTAL WORKING CAPITAL                                
       9.      COST OF PRODUCTION                                   
      10.      PROFITABILITY ANALYSIS                               
      11.      BREAK EVEN POINT                                     
      12.      RESOURCES OF FINANCE                           
      13.      INTEREST CHART                                       
      14.      DEPRECIATION CHART                                   
      15.      CASH FLOW STATEMENT                                   
      16.      PROJECTED BALANCE SHEET      
       

      How to Make Project Report?

      Detailed Project Report (DPR) includes Present Market Position and Expected Future Demand, Technology, Manufacturing Process, Investment Opportunity, Plant Economics and Project Financials. comprehensive analysis from industry covering detailed reporting and evaluates the position of the industry by providing insights to the SWOT analysis of the industry.

      Each report include Plant Capacity, requirement of Land & Building, Plant & Machinery, Flow Sheet Diagram, Raw Materials detail with suppliers list, Total Capital Investment along with detailed calculation on Rate of Return, Break-Even Analysis and Profitability Analysis. The report also provides a birds eye view of the global industry with details on projected market size and then progresses to evaluate the industry in detail.

      We can prepare detailed project report on any industry as per your requirement. 

      We can also modify the project capacity and project cost as per your requirement. If you are planning to start a business, contact us today.

      Detailed Project Report (DPR) gives you access to decisive data such as:

      • Market growth drivers
      • Factors limiting market growth
      • Current market trends
      • Market structure
      • Key highlights

      Overview of key market forces propelling and restraining market growth:

      • Up-to-date analyses of market trends and technological improvements
      • Pin-point analyses of market competition dynamics to offer you a competitive edge major competitors
      • An array of graphics, BEP analysis of major industry segments
      • Detailed analyses of industry trends
      • A well-defined technological growth with an impact-analysis
      • A clear understanding of the competitive landscape and key product segments

      Need Customized Project Report?

      1. Ask for FREE project related details with our consultant/industry expert.
      2. Share your specific research requirements for customized project report.
      3. Request for due diligence and consumer centric studies.
      4. Still haven't found what you're looking for? Speak to our Custom Research Team

      About Engineers India Research Institute:

      EIRI Board is a single destination for all the industry, company and country reports. We feature large repository of latest industry reports, leading and niche company profiles, and market statistics prepared by highly qualified consultants and verified by a panel of experts.

      Note: We can also prepare project report on any subject based on your requirement and country. If you need, we can modify the project capacity and project cost based on your requirement.

      Our reports provide an expansive market analysis of the sector by covering areas like growth drivers, trends prevailing in the industry as well as comprehensive SWOT analysis of the sector.

      Our Approach

      • Our research reports comprehensively cover Indian markets (can be modified as per your country), present investigation, standpoint and gauge for a time of five years*.
      • The market conjectures are produced on the premise of optional research and are cross-accepted through associations with the business players
      • We use dependable wellsprings of data and databases. What's more, data from such sources is handled by us and incorporated into the report

      Why buy EIRI reports?

      1. Our project reports include detailed analysis that help to get industry Present Market Position and Expected Future Demand.
      2. Offer real analysis driving variables for the business and most recent business sector patterns in the business
      3. This report comprehends the present status of the business by clarifying a complete SWOT examination and investigation of the interest supply circumstance
      4. Report gives investigation and top to bottom money related correlation of real players/competitors
      5. The report gives gauges of key parameters which foresees the business execution